Teledyne-lecroy Power Analyzer Package Bedienungsanleitung Seite 20

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 34
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 19
Power Analysis Software
Device dv/dt Test
This test measures the speed of a power device’s rate of change (dv/dt) during turn-on and turn-off.
1. Select the source channels and identify the switching zone.
2. On the Power Analysis tab choose Analysis Type Device and Test dv/dt & di/dt.
3. Select di/dt by checking the di/dt box in the Waveform section.
The power devices drain-to-source voltage (VDS) signal and the drain current are displayed on the
first grid. The derivative of the waveform’s dv/dt is displayed on the second grid. The di/dt waveform
is shown in the third grid.
4. Optionally, enter an Enhance Bit Value in the Setup section. This applies a filter to the data to reduce
noise.
5. Optionally, select Statistics to display mean, minimum and maximum values on the measurements
table. This helps to observe a consistent number.
6. Optionally, select Histicons to display a miniature histogram of the statistical measurements.
18
921326 Rev B
Seitenansicht 19
1 2 ... 15 16 17 18 19 20 21 22 23 24 25 ... 33 34

Kommentare zu diesen Handbüchern

Keine Kommentare